| AN29(F) series AC/DC electronic load has flexible parallel and online functions. When multiple units are connected in parallel, they can expand the current and power, meeting testing requirements of high-power single-phase power supplies. When three-phase online, a three-phase load is formed to meet the three-phase power testing requirements. Multiple units can also be connected in parallel to form a high-power three-phase electronic load. | 
    
    
    
      | Product Features
         | 
    
      | 
          CEPower Capacity: 1400W~ 8400WWorking voltage is low to 2V, and up to 350VrmsCurrent range: 10Arms~60Arms, peak current: 45A~ 270AFrequency range: 44~ 1000Hz, DCPeak factor: 1.4 ~ 5.0000Adjustable power factor, setting range 0-1.03 units in parallel to realize 3 phase loadWork mode: Constant current CC, constant resistance CR, constant power CPCurrent shift: current shift can be adjusted under testingDC: Static loading, dynamic loading, 40 programming stepsAC: Waveform simulation, sine, 3-15 harmonic, phase gate, crest factorUpper/lower limits adjustment, over limit alarming(GO/NG)Remote voltage detect sense port, used for precise measurement, eliminate wires voltage dropProtection function: Over voltage, over current, over power, over heat, DC reversed polarityMeasurement parameter: U, I, P, F and PF | 
    
    
    
      | Order information and extended functions
         | 
    
      | 
          CEAN29201(F): AC/DC Electronic Load 260V/10A/1400WAN29202(F): AC/DC Electronic Load 260V/20A/2800WAN29203(F): AC/DC Electronic Load 260V/30A/4200WAN29204(F): AC/DC Electronic Load 260V/40A/5600WAN29205(F): AC/DC Electronic Load 260V/50A/7000WAN29206(F): AC/DC Electronic Load 260V/60A/8400WRS485, GPIB optional | 
    
    
    
      |  | 
    
      | Waveform simulation | 
    
    
    
      |  | 
    
    
    
      |  | 
    
      | Power factor test: Simulate inductive and capacitive load, PF is from 0 to 1. If load current phase shift and PF are both need to set, PF can be set on front panel easily, do not need wire connection. | 
    
    
    
      |  | 
    
    
    
      | Regulation test: Under CC mode, load current is just changing setting value, not with DUT output voltage. Please refer to the characteristic curve | 
    
    
    
      |  | 
    
    
    
      | Dynamic performance test: Dynamic mode is switching between 2 levels in cycle, please refer to the characteristic curve. Dynamic current rising/dropping slope can be adjusted separately | 
    
    
    
      |  | 
    
    
    
      | Programmable steps: 4 groups, 10 steps/group. 4 groups can be parallel into 40 steps, and also can be divided into separated steps | 
    
    
    
      |  | 
    
    
    
      | Connect in parallel and series: 3 units in parallel to realize 3 phase load | 
    
    
    
      | Product Application
         | 
    
      | High power single-phase power supply test | 
    
    
    
      | Technical Specifications
         | 
    
      |  | 
    
    
    
      |  |